NF ISO 16889

NF ISO 16889

March 2022
Standard Current

Hydraulic fluid power - Filters - Multi-pass method for evaluating filtration performance of a filter element

This document describes the following: —    a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements; NOTE 1   For the background interlaboratory study used to verify the test methodology, see Annex D. —    a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics; —    a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≥ 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L; NOTE 2   It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities. —    a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A. This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge. This document applies to three test conditions: —    test condition 1, with a base upstream gravimetric level of 3 mg/L; —    test condition 2, with a base upstream gravimetric level of 10 mg/L; —    test condition 3, with a base upstream gravimetric level of 15 mg/L.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

March 2022

Number of pages

49 p.

Reference

NF ISO 16889

ICS Codes

23.100.60   Filters, seals and contamination of fluids

Classification index

E48-685

Print number

1

International kinship

Sumary
Hydraulic fluid power - Filters - Multi-pass method for evaluating filtration performance of a filter element

This document describes the following:

—    a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements;

NOTE 1   For the background interlaboratory study used to verify the test methodology, see Annex D.

—    a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics;

—    a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≥ 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L;

NOTE 2   It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.

—    a test using ISO medium test dust (ISO MTD) contaminant and a test fluid in accordance with Annex A.

This document is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.

This document applies to three test conditions:

—    test condition 1, with a base upstream gravimetric level of 3 mg/L;

—    test condition 2, with a base upstream gravimetric level of 10 mg/L;

—    test condition 3, with a base upstream gravimetric level of 15 mg/L.

Replaced standards (2)
NF ISO 16889
July 2008
Standard Cancelled
Hydraulic fluid power - Filters - Multi-pass method for evaluating filtration performance of a filter element

<p>ISO 16889:2008 describes a multi-pass filtration performance test with continuous contaminant injection for hydraulic fluid power filter elements; a procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics; a test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes less than or equal to 25 µm(c), and a final reservoir gravimetric level of less than 200 mg/L; and a test using ISO medium test dust contaminant and a test fluid.</p> <p>ISO 16889:2008 is intended to provide a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.</p> <p>ISO 16889:2008 applies to three test conditions: test condition 1, conducted with a base upstream gravimetric level of 3 mg/L; test condition 2, conducted with a base upstream gravimetric level of 10 mg/L; and test condition 3, conducted with a base upstream gravimetric level of 15 mg/L.</p>

NF ISO 16889/A1
July 2019
Standard Cancelled
Hydraulic fluid power - Filters - Multi-pass method for evaluating filtration performance of a filter element - Amendment 1

Le présent amendement modifie les pages 2 et 8 de la norme homologuée NF ISO 16889, de juillet 2008.

Table of contents
View the extract
  • Avant-propos
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Symboles
  • 5 Modes opératoires généraux
  • 6 Équipement d'essai
  • 7 Exactitude des instruments de mesure et variations des conditions d'essai
  • 8 Modes opératoires de validation du circuit de mesure des performances des filtres
  • 9 Récapitulatif des informations requises avant la réalisation des essais
  • 10 Préparation préliminaire
  • 11 Essais de performances du filtre
  • 12 Calculs
  • 13 Présentation des données
  • 14 Déclaration d'identification
  • Annexe A (normative) Propriété de base des fluides d'essai
  • Annexe B (informative) Instructions pour la conception du banc d'essai
  • Annexe C (informative) Exemples de calculs et de graphiques du rapport
  • Annexe D (informative) Résumé des données d'un essai interlaboratoires mené pour vérifier le mode opératoire du présent document
  • Bibliographie
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ