NF ISO 15690

NF ISO 15690

August 2013
Standard Current

Radiological protection - Recommendations for dealing with discrepancies between personal dosimeter systems used in parallel

ISO 15690:2013 provides recommendations for dealing with discrepancies between dosimeter systems used in parallel, in order to comply with established criteria and national regulations. ISO 15690:2013 gives guidelines for investigating and analysing the discrepancies between the results of personal dosimetry systems, using two or more dosimeters (often one passive dosimeter and one active dosimeter), worn in parallel by the same worker. ISO 15690:2013 identifies when the difference between measurements made by personal dosimetry systems used in parallel is considered significant and, hence, needs to be investigated. It specifies the treatment of this difference. In ISO 15690:2013, only the personal dose equivalent, Hp(10), from photon radiation is considered. Exposure to beta particles and neutrons might need to be taken into account when identified discrepancies are investigated. ISO 15690:2013 applies to situations where the period of wearing can be integrated to the same period of time for both systems.

View the extract
Main informations

Collections

National standards and national normative documents

Thematics

Sécurité, Gestion des risques et SST, QSE

Publication date

August 2013

Number of pages

20 p.

Reference

NF ISO 15690

ICS Codes

13.280   Radiation protection

Classification index

M60-519

Print number

1 - 02/08/2013

International kinship

Sumary
Radiological protection - Recommendations for dealing with discrepancies between personal dosimeter systems used in parallel

ISO 15690:2013 provides recommendations for dealing with discrepancies between dosimeter systems used in parallel, in order to comply with established criteria and national regulations.

ISO 15690:2013 gives guidelines for investigating and analysing the discrepancies between the results of personal dosimetry systems, using two or more dosimeters (often one passive dosimeter and one active dosimeter), worn in parallel by the same worker.

ISO 15690:2013 identifies when the difference between measurements made by personal dosimetry systems used in parallel is considered significant and, hence, needs to be investigated.

It specifies the treatment of this difference.

In ISO 15690:2013, only the personal dose equivalent, Hp(10), from photon radiation is considered. Exposure to beta particles and neutrons might need to be taken into account when identified discrepancies are investigated.

ISO 15690:2013 applies to situations where the period of wearing can be integrated to the same period of time for both systems.

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    1
  • 3.1 Doses opérationnelles
    2
  • 3.2 Dosimètres individuels
    2
  • 4 Évaluation des écarts entre les dosimètres utilisés en parallèle
    3
  • 4.1 Généralités
    3
  • 4.2 Comparaison entre les dosimètres utilisés en parallèle par les utilisateurs
    3
  • 4.3 Évaluation des écarts au-delà des critères recommandés
    4
  • 4.4 Documentation des écarts étudiés au niveau de la dose évaluée
    5
  • Annexe A (informative) Facteurs liés aux écarts entre les doses individuelles évaluées lorsque des systèmes dosimétriques sont utilisés en parallèle
    6
  • Bibliographie
    11
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ