NF EN ISO 22476-11

NF EN ISO 22476-11

May 2017
Standard Current

Geotechnical investigation and testing - Field testing - Part 11 : flat dilatometer test

ISO 22476-11:2017 establishes guidelines for the equipment requirements, execution of and reporting on flat dilatometer tests. NOTE This document fulfils the requirements for flat dilatometer tests as part of the geotechnical investigation and testing according to EN 1997‑1 and EN 1997‑2. The basic flat dilatometer test consists of inserting vertically into the soil a blade-shaped steel probe with a thin expandable circular steel membrane mounted flush on one face and determining two pressures at selected depth intervals: the contact pressure exerted by the soil against the membrane when the membrane is flush with the blade and, subsequently, the pressure exerted when the central displacement of the membrane reaches 1,10 mm. Results of flat dilatometer tests are used mostly to obtain information on soil stratigraphy, in situ state of stress, deformation properties and shear strength. It is also used to detect slip surfaces in clays. The flat dilatometer test is most applicable to clays, silts and sands, where particles are small compared to the size of the membrane.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

May 2017

Number of pages

25 p.

Reference

NF EN ISO 22476-11

ICS Codes

93.020   Earthworks. Excavations. Foundation construction. Underground works

Classification index

P94-521-11

Print number

1

International kinship

European kinship

EN ISO 22476-11:2017
Sumary
Geotechnical investigation and testing - Field testing - Part 11 : flat dilatometer test

ISO 22476-11:2017 establishes guidelines for the equipment requirements, execution of and reporting on flat dilatometer tests.

NOTE This document fulfils the requirements for flat dilatometer tests as part of the geotechnical investigation and testing according to EN 1997‑1 and EN 1997‑2.

The basic flat dilatometer test consists of inserting vertically into the soil a blade-shaped steel probe with a thin expandable circular steel membrane mounted flush on one face and determining two pressures at selected depth intervals: the contact pressure exerted by the soil against the membrane when the membrane is flush with the blade and, subsequently, the pressure exerted when the central displacement of the membrane reaches 1,10 mm.

Results of flat dilatometer tests are used mostly to obtain information on soil stratigraphy, in situ state of stress, deformation properties and shear strength. It is also used to detect slip surfaces in clays. The flat dilatometer test is most applicable to clays, silts and sands, where particles are small compared to the size of the membrane.

Table of contents
View the extract
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes, définitions et symboles
  • 4 Matériel
  • 5 Mode opératoire d'essai
  • 6 Résultats d'essai
  • 7 Rapport
  • Annexe A Exemples de formules d'interprétation
  • Bibliographie
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ