ISO 13163:2021

ISO 13163:2021

July 2021
International standard Current

Water quality - Lead-210 - Test method using liquid scintillation counting

This document specifies a method for the measurement of 210Pb in all types of waters by liquid scintillation counting (LSC). The method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample is necessary. Lead‑210 activity concentration in the environment can vary and usually ranges from 2 mBq l-1 to 300 mBq l-1 [27][28]. Using currently available liquid scintillation counters, the limit of detection of this method for 210Pb is generally of the order of 20 mBq l-1 to 50 mBq l-1, which is lower than the WHO criteria for safe consumption of drinking water (100 mBq l−1).[4][6] These values can be achieved with a counting time between 180 min and 720 min for a sample volume from 0,5 l to 1,5 l. Higher activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both. The method presented in this document is not intended for the determination of an ultra-trace amount of 210Pb. The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and counting efficiency). The method described in this document is applicable to an emergency situation. The analysis of Pb adsorbed to suspended matter is not covered by this method. It is the user’s responsibility to ensure the validity of this test method for the water samples tested.

View the extract
Main informations

Collections

International ISO standards

Publication date

July 2021

Number of pages

22 p.

Reference

ISO 13163:2021

ICS Codes

13.060.60   Examination of physical properties of water
17.240   Radiation measurements

Print number

1
Sumary
Water quality - Lead-210 - Test method using liquid scintillation counting

This document specifies a method for the measurement of 210Pb in all types of waters by liquid scintillation counting (LSC).

The method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling, and test sample preparation. Filtration of the test sample is necessary. Lead‑210 activity concentration in the environment can vary and usually ranges from 2 mBq l-1 to 300 mBq l-1 [27][28].

Using currently available liquid scintillation counters, the limit of detection of this method for 210Pb is generally of the order of 20 mBq l-1 to 50 mBq l-1, which is lower than the WHO criteria for safe consumption of drinking water (100 mBq l−1).[4][6] These values can be achieved with a counting time between 180 min and 720 min for a sample volume from 0,5 l to 1,5 l. Higher activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both. The method presented in this document is not intended for the determination of an ultra-trace amount of 210Pb.

The range of application depends on the amount of dissolved material in the water and on the performance characteristics of the measurement equipment (background count rate and counting efficiency).

The method described in this document is applicable to an emergency situation.

The analysis of Pb adsorbed to suspended matter is not covered by this method.

It is the user’s responsibility to ensure the validity of this test method for the water samples tested.

Replaced standards (1)
ISO 13163:2013
October 2013
International standard Cancelled
Water quality - Lead-210 - Test method using liquid scintillation counting

<p>ISO 13163 specifies the determination of lead-210 (210Pb) activity concentration in samples of all types of water using liquid scintillation counting (LSC). For raw and drinking water, the sample should be degassed in order to minimize the ingrowth of <sup>210</sup>Pb from radon-222 (<sup>222</sup>Rn).</p> <p>Using currently available liquid scintillation counters, this test method can measure the <sup>210</sup>Pb activity concentrations in the range of less than 20 mBq⋅l<sup>-1</sup> to 50 mBq⋅l<sup>-1</sup>. These values can be achieved with a counting time between 180 min and 720 min for a sample volume from 0,5 l to 1,5 l.</p> <p>Higher <sup>210</sup>Pb activity concentrations can be measured by either diluting the sample or using smaller sample aliquots or both.</p> <p>It is the laboratory's responsibility to ensure the suitability of this test method for the water samples tested.</p>

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ