FD T90-119

FD T90-119

July 1998
Published document Cancelled

Water quality. . Determination of mineral elements (Ai, Sb, Ag, As, Ba, Co, Cu, Sn, Mn, Mo, Ni, Pb, Se, Ti, V). . Atomic absorption spectrometric method with electrothermal atomization.

Le présent document s'adresse aux laboratoires ayant à doser certains éléments minéraux dans la plupart des types d'eaux à l'état de traces.

Main informations

Collections

National standards and national normative documents

Publication date

July 1998

Number of pages

11 p.

Reference

FD T90-119

ICS Codes

13.060.50   Examination of water for chemical substances

Classification index

T90-119

Print number

1 - 05/08/1998

International kinship

ISO/DIS 15586
Sumary
Water quality. . Determination of mineral elements (Ai, Sb, Ag, As, Ba, Co, Cu, Sn, Mn, Mo, Ni, Pb, Se, Ti, V). . Atomic absorption spectrometric method with electrothermal atomization.

Le présent document s'adresse aux laboratoires ayant à doser certains éléments minéraux dans la plupart des types d'eaux à l'état de traces.
Replaced standards (1)
FD T90-119
November 1996
Published document Cancelled
Water testing. Determination of mineral elements (Al, Sb, Ag, As, Ba, Cd, Cr, Co, Cu, Sn, Mn, Mo, Ni, Pb, Se, Ti, V). Atomic absorption spectrometric method with electrothermal atomization.

Le présent document s'adresse aux laboratoires ayant à doser certains éléments minéraux dans la plupart des types d'eaux à l'état de traces.

Standard replaced by (1)
NF EN ISO 15586
May 2004
Standard Current
Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace

<p>ISO 15586:2003 includes principles and procedures for the determination of trace levels of: Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, and Zn in surface water, ground water, drinking water, wastewater and sediments, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable to the determination of low concentrations of elements.</p> <p>The detection limit of the method for each element depends on the sample matrix as well as of the instrument, the type of atomizer and the use of chemical modifiers. For water samples with a simple matrix (i.e. low concentration of dissolved solids and particles), the method detection limits will be close to instrument detection limits. The minimum acceptable detection limit values for a 20-microlitre sample volume are specified.</p>